Bosh sahifa - Yangiliklar - Batafsil

Ultrasonik tozalagichning umumiy nosozliklari va echimlari

Ultrasonik tozalagichning umumiy nosozliklari va echimlari


1. Transduserning shikastlanishi:

Tahlil: Ishga tushirish va ishlatish holatida uzoq vaqt davomida ultratovushli tozalash mashinasining harorati asta-sekin ko'tarilib, transduserning kolloid erishi tushishiga yoki transduser keramikasi qisman sinishiga olib kelishi mumkin.


Detection and solution: use shaking meter to measure the insulation strength of the transducer. The insulation strength can not be used below 200M ω, and a new transducer must be replaced.


Transduserning ichki keramikasi ham uzoq muddat foydalanishdan-yorilib, to'g'ri ishlay olmaydi.


2. Ultrasonik tozalagichning sug'urta zarari:

Yuklashdan so'ng, agar kuch ko'rsatilmasa, hech qanday harakat bo'lmasa, birinchi navbatda elektr o'rindig'ining xavfsizligi buzilganligini ko'rish uchun.


Tahlil: foydalanuvchi topraklama chizig'i va jonli chiziq yoki nol chiziq aralashgan bo'lishi mumkin va topraklama yo'q (tuproq simi mashina qobig'i bilan bog'langan), ultratovushli tozalash mashinasining qisqa tutashuvi, komponentlarning qarishi qisqa tutashuvi hodisasi bo'lishi mumkin, natijada sug'urta zarar.


Aniqlash va hal qilish: tanaffus bor yoki yo'qligini bilish uchun sug'urtani oling, singan yoki buzilganligini o'lchash uchun multimetrdan foydalaning, yangi qurilmani almashtiring.


3, ultratovushli tozalagichning quvvat trubkasi shikastlangan:

Tahlil: anakartdagi quvvat trubkasi uzoq vaqt davomida ultratovushli tozalash uchun ishlatiladi yoki tozalash suyuqligi uzoq vaqt davomida juda oz bo'ladi, shuning uchun quvvat trubkasi qisqa tutashuvi.


Detection and solution: when the power tube is connected on the motherboard, use a multimeter to measure the resistance of the pins on both sides of the power tube, which should be about 22 ω under normal circumstances. After taking off the power tube (disconnected from the motherboard), the measurement of its various pins should be impenetrable.


4, regulyator trubkasi shikastlangan

Tahlil: regulyator trubasining shikastlanishi, odatda, uning qarshiligi kichik yoki qisqa tutashuvdan keyin quvvat trubkasi ishga tushirilishidan kelib chiqadi va u kamdan-kam hollarda shikastlanadi.


Detection and solution: according to the characteristics of the diode, leading, reverse ending. Multimeter diode measurement, forward resistance value of about 70 ω, reverse ∞. If the value deviation is too large or the positive resistance value is ∞, replace the regulator tube.


5, ko'prikning shikastlanishi (diodli rektifikator davri)

Tahlil: regulyator trubasining holati bilan bir xil


Aniqlash va hal qilish: shuningdek, diod xususiyatlariga asoslanadi (ko'prikning o'zi diodlardan qilingan)


6, indüktans, izolyatsiya transformatorining shikastlanishi

Tahlil: chunki ultratovushli tozalash uzoq vaqt davomida, indüktans, transformator sovutish elementi bo'lib, o'zining yuqori harorat tufayli erishi, kuyishi, qisqa tutashuvga olib kelishi mumkin.


Aniqlash va hal qilish: induktor, transformator shikastlanishi, aksariyat hollarda intuitiv ravishda kuyish izlarini ko'rishi, yangi qurilmani almashtirishi mumkin.


7, boshqaruv paneli shikastlanishi (sozlanishi mumkin bo'lgan ultratovush tozalagich)

Tahlil: Komponentlarning qarishi bilan bog'liq bo'lgan uzoq vaqt davomida doimiy ish uchun ultratovushli tozalash, ba'zan esa tozalovchi suyuqlikka.


Aniqlash va hal qilish: ultratovushli tozalash mashinasi ishlamay qolganda boshqaruv paneli va asosiy plata o'rtasidagi aloqani uzing. Anakartni elektrlashtiring, masalan, ultratovushli tozalash mashinasi ishi, boshqaruv platasining shikastlanishi, o'zgartirilishi kerak.

So'rov yuborish

Sizga ham yoqishi mumkin